Send documentation comments to mdsfeedback-doc@cisco.com
62-35
Cisco MDS 9000 Family Fabric Manager Configuration Guide
OL-17256-03, Cisco MDS NX-OS Release 4.x
Chapter 62 Configuring Call Home
Message Contents
Server ID If the message is generated from the fabric switch, it is the unique
device identifier (UDI) of the switch.
Format: type@Sid@serial, where
• type is the product model number from backplane SEEPROM.
• @ is a separator character.
• Sid is “C” identifying the serial ID as a chassis serial number·
• serial is the number identified by the Sid field.
Example: “DS-C9509@C@12345678
/mml/header/serverId -
-blank-
Message description Short text describing the error. /mml/body/msgDesc -
ch:MessageDescription
Device name Node that experienced the event. This is the host name of the device. /mml/body/sysName -
ch:SystemInfo/Name
Contact name Name of person to contact for issues associated with the node
experiencing the event.
/mml/body/sysContact -
ch:SystemInfo/Contact
Contact e-mail E-mail address of person identified as contact for this unit. /mml/body/sysContacte-mail -
ch:SystemInfo/Contacte-mail
Contact phone
number
Phone number of the person identified as the contact for this unit. /mml/body/sysContactPhone
Number -
ch:SystemInfo/ContactPhone
Number
Street address Optional field containing street address for RMA part shipments
associated with this unit.
/mml/body/sysStreetAddress -
ch:SystemInfo/StreetAddress
Model name Model name of the switch. This is the specific model as part of a product
family name.
/mml/body/chassis/name -
rme:Chassis/Model
Serial number Chassis serial number of the unit. /mml/body/chassis/serialNo -
rme:Chassis/SerialNumber
Chassis part number Top assembly number of the chassis. /mml/body/fru/partNo -
rme:chassis/Card/PartNumber
Chassis hardware
version
Hardware version of chassis. /mml/body/chassis/hwVersion
-
rme:Chassis/HardwareVersion
Supervisor module
software version
Top level software version. /mml/body/fru/swVersion -
rme:chassis/Card/SoftwareIde
ntity
Affected FRU name Name of the affected FRU generating the event message. /mml/body/fru/name -
rme:chassis/Card/Model
Affected FRU serial
number
Serial number of affected FRU. /mml/body/fru/serialNo -
rme:chassis/Card/SerialNumb
er
Affected FRU part
number
Part number of affected FRU. /mml/body/fru/partNo -
rme:chassis/Card/PartNumber
Table 62-6 Reactive Event Message Format (continued)
Data Item
(Plain text and XML)
Description
(Plain text and XML)
XML Tag