EasyManua.ls Logo

Dell PowerConnect 8024 - Sflow Polling

Dell PowerConnect 8024
1132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1010 Sflow Commands
before trying to claim it. The entry is claimed by setting the owner string to a non-null value.
The entry must be claimed before assigning a receiver to a sampler or poller. (Range: 1–127
characters).
rcvr_timeout
The time, in seconds, remaining before the sampler or poller is released and
stops sending samples to the receiver. A management entity wanting to maintain control of
the sampler is responsible for setting a new value before the old one expires. (Range:
0–4294967295 seconds).
port
The destination Layer4 UDP port for sFlow datagrams. (Range: 1–65535).
Default Configuration
No receivers are configured by default.
The default IP address is 0.0.0.0
The default maximum datagram size is 1400.
The default owner string is the empty string.
The default receiver timeout is 0.
The default port is 6343.
Command Mode
Global Configuration mode.
User Guidelines
This command has no user guidelines
Example
console(config)#sflow 1 destination owner 1 timeout 2000
console(config)#sflow 1 destination maxdatagram 500
console(config)#sflow 1 destination 30.30.30.1 560
sflow polling
Use the sflow polling command to enable a new sflow poller instance for this data source if
rcvr_idx is valid. Use the “no” form of this command to reset poller parameters to the defaults.
Syntax
sflow
rcvr-index
polling ethernet
interfaces
poll-interval

Table of Contents

Other manuals for Dell PowerConnect 8024

Related product manuals