600 IGMP Proxy Commands
console(config-if-vlan15)#ip igmp-proxy
ip igmp-proxy reset-status
Use the ip igmp-proxy reset-status command in Interface Configuration mode to reset the host
interface status parameters of the IGMP Proxy router. This command is valid only when IGMP
Proxy is enabled on the interface.
Syntax
ip igmp-proxy reset-status
Default Configuration
This command has no default configuration.
Command Mode
Interface Configuration (VLAN) mode
User Guidelines
This command has no user guidelines.
Example
The following example resets the host interface status parameters of the IGMP Proxy router.
console(config)#interface vlan 15
console(config-if-vlan15)#ip igmp-proxy reset-status
ip igmp-proxy unsolicited-report-interval
Use the ip igmp-proxy unsolicited-report-interval command in Interface Configuration mode
to set the unsolicited report interval for the IGMP Proxy router. This command is valid only if
IGMP Proxy on the interface is enabled.
Syntax
ip igmp-proxy unsolicited-report-interval
seconds
seconds
Unsolicited report interval. (Range: 1-260 seconds)
Default Configuration
The default configuration is 1 second.

Table of Contents

Other manuals for Dell PowerConnect 8024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 8024 and is the answer not in the manual?

Dell PowerConnect 8024 Specifications

General IconGeneral
Switching Capacity480 Gbps
StackableYes
Device TypeSwitch
Enclosure TypeRack-mountable
Power RedundancyOptional
Width17.3 in
Height1.7 in
Jumbo Frame SupportYes
Ports24 x 10 Gigabit SFP+
ManagementWeb-based GUI, Command Line Interface (CLI), SNMP
VLAN SupportYes
Power SupplyInternal
Routing ProtocolStatic routing
FeaturesQuality of Service (QoS), VLAN support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z
Operating Temperature0 to 45 °C
Storage Temperature-20 to 70 °C
Relative Humidity10% to 90% (non-condensing)
MAC Address Table Size32, 000 entries

Related product manuals