1058 Syslog Commands
level
— Limits the message logging to a specified level buffer. (Range:
emergency, alert,
critical, error, warning, notice, info, debug
)
Default Configuration
The default value for
level
is info.
Command Mode
Global Configuration mode
User Guidelines
All the syslog messages are logged to the internal buffer. This command limits the commands
displayed to the user.
Example
The following example limits syslog messages displayed from an internal buffer based on the
severity level “error.”
console(config)#logging buffered error
logging console
Use the logging console command in Global Configuration mode to limit messages logged to
the console based on severity. To disable logging to the console terminal, use the no form of this
command.
Syntax
logging console
level
no logging console
level
— Limits the logging of messages displayed on the console to a specified level. (Range:
emergency, alert, critical, error, warning, notice, info, debug)
Default Configuration
The default value for
level
is info.
Command Mode
Global Configuration mode
User Guidelines
This command has no user guidelines.