976 RMON Commands
•
revent
— The index of the Event that is used when a rising threshold is crossed. (Range: 1-
65535)
•
fevent
— The Event index used when a falling threshold is crossed. (Range: 1- 65535)
•
type
type
— The sampling method for the selected variable and calculating the value to be
compared against the thresholds. If the method is
absolute
, the value of the selected variable
is compared directly with the thresholds at the end of the sampling interval. If the method is
delta
, the selected variable value at the last sample is subtracted from the current value, and
the difference compared with the thresholds.
•
startup
direction
— The alarm that may be sent when this entry is first set to valid. If the first
sample (after this entry becomes valid) is greater than or equal to the
rthreshold
, and
direction
is equal to
rising
or
rising-falling
, then a single rising alarm is generated. If the first
sample (after this entry becomes valid) is less than or equal to the
fthreshold
, and
direction
is
equal to
falling
or
rising-falling
, then a single falling alarm is generated.
•
owner
name
— Enter a name that specifies who configured this alarm. If unspecified, the
name is an empty string.
Default Configuration
The following parameters have the following default values:
•
type
type
— If unspecified, the type is
absolute
.
•
startup
direction
— If unspecified, the startup direction is
rising-falling
.
Command Mode
Global Configuration mode
User Guidelines
This command has no user guidelines.
Example
The following example configures the following alarm conditions:
•Alarm index —
1
•Variable
identifier —
1.3.6.1.2.1.2.2.1.10.5
• Sample interval —
10 seconds
• Rising threshold —
500000
• Falling threshold —
10
• Rising threshold event index —
1
• Falling threshold event index —
1