RMON Commands 979
number
— Alarm index. (Range: 1–65535)
Default Configuration
This command has no default configuration.
Command Mode
User EXEC mode
User Guidelines
This command has no user guidelines.
Example
The following example displays RMON 1 alarms.
console> show rmon alarm 1
Alarm 1
-------
OID: 1.3.6.1.2.1.2.2.1.10.1
Last sample Value: 878128
Interval: 30
Sample Type: delta
Startup Alarm: rising
Rising Threshold: 8700000
Falling Threshold: 78
Rising Event: 1
Falling Event: 1
Owner: CLI
The following table describes the significant fields shown in the display:
Field Description
Alarm Alarm index.
OID Monitored variable OID.