Link Layer Discovery Protocol (LLDP) Commands
779 Cisco Sx350 Ph. 2.2.5 Devices - Command Line Interface Reference Guide
36
Parameters
reinit
seconds
—Specifies the minimum time in seconds an LLDP port waits before
reinitializing LLDP transmission.(Range: 1–10)
Default Configuration
2 seconds
Command Mode
Global Configuration mode
Example
switchxxxxxx(config)#
lldp reinit
4
36.20 lldp timer
To specify how often the software sends LLDP updates, use the lldp timer Global
Configuration mode command. To restore the default configuration, use the no
form of this command.
Syntax
lldp timer
seconds
no lldp timer
Parameters
timer
seconds
—Specifies, in seconds, how often the software sends LLDP
updates (range: 5-32768 seconds).
Default Configuration
30 seconds.
Command Mode
Global Configuration mode

Table of Contents