Power over Ethernet (PoE) Commands
Cisco Sx350 Ph. 2.2.5 Devices - Command Line Interface Reference Guide 892
45
Example
The following example turns on the device discovery protocol on port 4.
switchxxxxxx(config)#
interface
gi1
4
switchxxxxxx(config-if)#
power inline auto
45.2 power inline inrush test disable
To disable the inrush test (a hardware test that checks input surge current for PoE
devices), use the power inline inrush test disable Global Configuration mode
command. To enable the inrush test, use the no form of this command.
Syntax
power inline inrush test disable
no power inline inrush test disable
Parameters
N/A.
Default Configuration
Inrush test is enabled.
Command Mode
Global Configuration mode
Example
The following example disable inrush test.
switchxxxxxx(config)#
power inline inrush test disable