Power over Ethernet (PoE) Commands
Cisco Sx350 Ph. 2.2.5 Devices - Command Line Interface Reference Guide 898
45
User Guidelines
Changing the PoE limit mode of the system will turn the power OFF and ON for all
PoE ports.
Example
The following example sets the power limit to class.
switchxxxxxx(config)#
power inline limit-mode
class
"Changing the PoE limit mode of the system will turn the power OFF and ON for all
PoE ports. Are you sure? [y/n]"
45.10 power inline four-pair forced
To configure the inline power to enabled the spare pair, use the power inline
four-wire forced Interface Configuration mode command.
Syntax
power inline four-pair forced
no power inline four-pair forced
Parameters
Default Configuration
The default configuration is set to no four-pair forced.
Command Mode
Interface (Ethernet) Configuration mode
User Guidelines
This command should only be used for ports that are connected to devices that do
not support the CDP/LLDP protocol or the new 4-wire power via MDI TLV (like
UPOE splitter).
The command is used to force the spare pair to supply power, this allows the
usage of 60 Watts PoE.
CDP/LLDP will reflect power allocated of 60W regardless of power requested.