System Management Commands 1091
This example displays information about all units in the stack.
console>show switch
Management Standby Preconfig Plugged-in Switch Code 
Sw Status Status Model ID Model ID Status Version
-------------------------------------------------------------
1 Mgmt Sw PC8024 PC8024 OK 3.0.0.1
Different fields in the display are explained as follows:
Model Identifier This field displays the model identifier for this switch. 
Model Identifier is a 32-character field assigned by the 
switch manufacturer to identify the switch.
Switch Status This field displays the switch status. Possible values are OK, 
Unsupported, Code Mismatch, Config Mismatch, or Not 
Present.
Switch Description This field displays the switch description.
Expected Code Version This field indicates the expected code version.
Detected Code Version This field displays the version of code running on this 
switch. If the switch is not present and the data is from 
preconfiguration, the code version is “None.”
Detected Code in Flash This field displays the version of code that is currently 
stored in FLASH memory on the switch. This code will 
execute after the switch is reset. If the switch is not present 
and the data is from pre-configuration, then the code 
version is “None.”
Boot Code Version This field displays the version of the boot strapping code.
Up Time This field displays the system up time.
Unit Description
Switch This field displays the unit identifier assigned to the switch.
Management Status This field indicates whether the switch is the Management 
Switch, a stack member, or the status is unassigned.
Preconfigured Model Identifier This field displays the model identifier of a preconfigured 
switch ready to join the stack. The Model Identifier is a 32-
character field assigned by the switch manufacturer to 
identify the switch. 
Unit Description