System Management Commands
1191 Cisco Sx350 Ph. 2.2.5 Devices - Command Line Interface Reference Guide
62
power - Display the power supply status
fan
Displays the fan status
temperature status—Displays the temperature status
Command Mode
User EXEC mode
User Guidelines
The power parameters displays power supply information.
Main Power supply statuses:
Active - power supply is used.
Failure - Main power has failed.
PD
Power supply statuses:
Active - power supply is used.
Available - Power supply is connected but is not used.
Not Connected - The PD port is not connected or not connected to PSE.
The fan and temperature status parameters are available only on devices on which
FAN and/or temperature sensor are installed.
Fan status can be one of:
Fans OK, redundant fan Ready - The fan/s functions correctly.
Fans OK, redundant fan Active - One of the fans failed and is backed-up by
the redundant fan.
Fail - Several fans failed.
N/A - No fan installed.
Sensor status can be one of:
OK - The sensor/s functions correctly.
Failure - The sensor/s failed.
NA - No sensor is installed.
Temperature can be one of:

Table of Contents