Power over Ethernet (PoE) Commands
Cisco Sx350 Ph. 2.2.5 Devices - Command Line Interface Reference Guide 904
45
Following is a list of port status values:
Port is on - Valid capacitor/resistor detected.
Port is on - Valid resistor/capacitor detected.
Port is on - 4 pairs.
Port is on - Forced 4 pairs.
Port is off - Main supply voltage is high.
Port is off - Main supply voltage is low.
Port is off - Hardware pin disables all ports.
Class Power consumption classification of the device
(0-4).
Device Description of the device type set by the user.
Priority Port inline power management priority. The
possible values are Critical, High or Low.
Port status The port status on/off with detailed reason (see
bellow for details).
Port standard 802.3AF
/802.3AT /60W POE.
Admin power
limit
Port limit in watts used when the Port limit
mode is Enabled.
Time Range The name of the time range associated with the
interface.
Link partner
standard
802.3AF/802.3AT/60W POE.
Operational
Power Limit
Port actual power limit in watts.
Current (mA) Port current in Milli-Ampere.
Voltage (V) Port voltage in volts.
Overload
Counter
Counts the number of overload conditions
detected.
Short Counter Counts the number of short conditions
detected.
Denied Counter Counts the number of times power was denied.
Absent Counter Counts the number of times power was
removed because device dropout was
detected.
Invalid Signature
Counter
Counts the number of times an invalid signature
of a device was detected.
Field Description