6F2S1914 (0.49)
GRL200 (Soft 033 & 037)
- 878 -
command is not identical to “IED test status”.
6
Note: The “Event suppression” function can detect chattering in BI circuits. (See section
4.8.6(i)-3)
7
Note: A supervision of the Binary IO module can detect connection errors for BI circuits.
8
Note: The Common control (CMNCTRL) function can test and check the operation-
direction of logic. When the user sets Off for scheme switch [SCDEN], operation of
the logic is blocked if the logic is running in the same operation-direction
compared with the previous operation-direction. Alternatively, if On is set for the
scheme switch, the logic is not blocked.
9
Note: The user must program the PLC logic Control hierarchy condition”. The user
must connect the Control hierarchy condition” to the select condition logic using
the connection point DPOS01IN_TMP_28”. For more information, see Chapter
Control and monitoring application: Control hierarchy
. See PLC#3 of Table
4.8-7.Note that the logic outputs are generated separately for both On and Off.
(viii) Signal name and number
Note: The user should note the meaning of the following descriptions as shown in
column M/O of each table:
“O” indicates that the signal is provided for optional use.
M indicated that the user should map/set/configure the signal; otherwise, the
user experience an operational failure if the default settings are used.
N/A indicates that that the user cannot change the state of the signal.
Table 4.8-14 PLC connection points (Input point for PLC#1 User configurable condition)
Signal Number
Signal Name
Description
M/O
512001 810301EE57
DPOS01IN_TMP_35
DPOS01 user configurable condition(PLC#1)
O
512001 810302EE57
DPOS01IN_TMP_35
DPOS02 user configurable condition(PLC#1)
O
512001 810303EE57
DPOS01IN_TMP_35
DPOS03 user configurable condition(PLC#1)
O
.
.
..
512001 810348EE57
DPOS72IN_TMP_35
DPOS72 user configurable condition(PLC#1)
O
Table 4.8-15 PLC connection points (Input point for PLC#2 User configurable condition)
Signal Number
Signal Name
Description
M/O
512001 820301EE5E
DPOS01IN_TMP_42
DPOS01 user configurable condition(PLC#2)
O
512001 820302EE5E
DPOS02IN_TMP_42
DPOS02 user configurable condition(PLC#2)
O
512001 820303EE5E
DPOS03IN_TMP_42
DPOS03 user configurable condition(PLC#2)
O
512001 820348EE5E
DPOS72IN_TMP_42
DPOS72 user configurable condition(PLC#2)
O
Table 4.8-16 PLC connection points (Input point for PLC#3 User configurable condition)
Signal Number
Signal Name
Description
M/O
512001 800301EE53
DPOS01IN_TMP_34
DPOS01 user configurable condition(PLC#3)
O