4.9.9 Signal
Signal monitoring points in TPOS01
TPOS(FunctionID:513001)
Element ID
Name
Description
8004001FA3
TPOS00_CH_EC_LCD
TPOS00 count change execute command by LCD
8004001D5E
TPOS00_CH_EC_OWS
TPOS00 count change execute command by OWS(HMI)
8004001D5F
TPOS00_CH_EC_RCC
TPOS00 count change execute command by RCC
8004001D60
TPOS00_CH_EC_RMT
TPOS00 count change execute command by Remote
8004001FA2
TPOS00_CH_SC_LCD
TPOS00 count change select command by LCD
8004001D5B
TPOS00_CH_SC_OWS
TPOS00 count change select command by OWS(HMI)
8004001D5C
TPOS00_CH_SC_RCC
TPOS00 count change select command by RCC
8004001D5D
TPOS00_CH_SC_RMT
TPOS00 count change select command by Remote
3204011D20
TPOS01_ALL_CNT_VAL
TPOS01 all count value
0004011F7C
TPOS01_AUTO_SIG
TPOS01 Auto sequence signal
8304011E9C
TPOS01_CCF_FCT_CS
TEMP21
8704011E96
TPOS01_CC_FS
TEMP19
8604011E95
TPOS01_CC_SS
TEMP18
8804011E9B
TPOS01_CC_ST_ERR
TEMP39
0004011F7D
TPOS01_CMNCTRL_SIG
TPOS01 control receive signal
8604011F8D
TPOS01_CNT_CS07
TPOS01 count change selected fail condition signal
0004011D91
TPOS01_CNT_SEL
TPOS01 count change selected signal(stSeld) for SAS
0004011F7A
TPOS01_CNT_SIG
TPOS01 Count correction signal
8004011E9E
TPOS01_CTR_SGC
TPOS01 control logic stage(select command check)
8004011EA0
TPOS01_CTR_SGE
TPOS01 control logic stage(execute command check)
8304011E9D
TPOS01_CTR_SGN
TPOS01 control logic stage(unselected)
8004011E9F
TPOS01_CTR_SGS
TPOS01 control logic stage(selected)
8B04011EA2
TPOS01_CTR_SGU
TPOS01 control logic stage(under selection)
8904011FAB
TPOS01_CTR_SGUCN
TPOS01 count change selected signal
8904011FB1
TPOS01_CTR_SGURS
TPOS01 reset time selected signal
8004011EA1
TPOS01_CTR_SGW
TPOS01 control logic stage(wait for change)
8104011E9A
TPOS01_ECF_FCT_EIS
TPOS01 execute command fail factor signal except interlock/synchronism check
8004011D58
TPOS01_EC_LCD
TPOS01 execute command by LCD
8004011D55
TPOS01_EC_OWS
TPOS01 execute command by OWS(HMI)
8004011D59
TPOS01_EC_PLC
TPOS01 execute command by PLC
8004011D56
TPOS01_EC_RCC
TPOS01 execute command by RCC
8004011D57
TPOS01_EC_RMT
TPOS01 execute command by Remote
8004011F55
TPOS01_EC_ST_ERR
TPOS01 execute command mode err
0004011D97
TPOS01_EX_BO_OPOK
TPOS01 execute binary output signal for SAS
8004011E93
TPOS01_EX_CMP
TPOS01 execute complete signal
8F04011F58
TPOS01_EX_CMP_TMO
TPOS01 timeout after execute completion
8904011FB0
TPOS01_EX_CMP_TMOCN
TPOS01 count change timeout after execute completion
8904011FB6
TPOS01_EX_CMP_TMORS
TPOS01 reset time timeout after execute completion
8904011F6F
TPOS01_EX_CS01
TPOS01 response supervisory timer for P1
8A04011F70
TPOS01_EX_CS02
TPOS01 response supervisory timer for P2
8B04011F72
TPOS01_EX_CS03
TPOS01 P1 timer for under execution
8C04011F73
TPOS01_EX_CS04
TPOS01 P2 timer for under execution
8A04011F71
TPOS01_EX_CS05
TPOS01 response supervisory timer for P3
8C04011F74
TPOS01_EX_CS06
TPOS01 P3 timer for under execution
8604011E91
TPOS01_EX_FFL
TPOS01 execute fail signal by fixedlogic
8504011E8F
TPOS01_EX_SFL
TPOS01 execute success signal by fixedlogic
8404011F43
TPOS01_FLT_DET1
TPOS01 Faulty Detected (3 phase concentration data only)
8104011F42
TPOS01_FLT_STA
TPOS01 Faulty Start
8204011E8B
TPOS01_F_CS
TPOS01 execute command fail condition signal
3104011D01
TPOS01_LCD_ST
TPOS01 state for LCD
3104011D00
TPOS01_MMC_ST
TPOS01 state for MIMIC