Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 1007
8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_NSet_1
14.1.98.6 Ramp function generator for the main setpoint
The setpoint is now led via a ramp function generator with linear characteristic. The ramp
function generator converts setpoint step-changes at the input into a ramp.
[14-31] Acceleration and deceleration times
t
ir
and t
if
are the desired times for changing between w1 and w2.
S-ramps are possible by selecting S-ramp times.
The t
ir
/t
if
values are converted into the required Ti times according to the following
formula:
Setting and selection of Ti times
Via parameters, you can select 16 different Tir and Tif times each for the ramp function
generator.
The selection is made via the binary coded selection inputs bTI1 ... bTI8:
w1, w2 = change of the main setpoint as a function of t
ir
and t
if
RFG-OUT = output of the ramp function generator
RFG-OUT
100 %
w2
w1
0%
t
ir
t
ir
T
ir
T
ir
Selection inputs Used
Acceleration time
Used
Deceleration
time
bTI8 bTI4 bTI2 bTI1
FALSE FALSE FALSE FALSE C00012
C00013
FALSE FALSE FALSE TRUE C00101/1 C00103/1
FALSE FALSE TRUE FALSE C00101/2 C00103/2
FALSE FALSE TRUE TRUE C00101/3 C00103/3
FALSE TRUE FALSE FALSE C00101/4 C00103/4
FALSE TRUE FALSE TRUE C00101/5 C00103/5
FALSETRUE TRUEFALSEC00101/6 C00103/6
FALSE TRUE TRUE TRUE C00101/7 C00103/7
TRUE FALSE FALSE FALSE C00101/8 C00103/8
TRUE FALSE FALSE TRUE C00101/9 C00103/9
TRUE FALSE TRUE FALSE C00101/10 C00103/10
TRUE FALSE TRUE TRUE C00101/11 C00103/11
TRUE TRUE FALSE FALSE C00101/12 C00103/12
TRUE TRUE FALSE TRUE C00101/13 C00103/13
T
ir
t
ir
100 %
w2 w1–
----------------------
⋅= T
if
t
if
100 %
w2 w1–
----------------------
⋅=
efesotomasyon.com - Lenze