8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01224
772 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
 
C01224
C01225
C01226
Parameter | Name:
C01224 | MCK: Ref. speeds
Data type: INTEGER_32
Index: 23351
d
 = 5B37
h
Speeds for reference search/homing
Homing
Setting range (min. value | unit | max. value)
0.0000 unit/s 214748.3647
Subcodes Lenze setting Info
C01224/1 720.0000 unit/s MCK: Ref. initial speed
 • Starting speed for approaching the pre-stop signals.
C01224/2 180.0000 unit/s MCK: Ref. search speed
 • Search speed for detecting the reference initiator.
; Read access ; Write access  CINH  PLC STOP  No transfer  COM  MOT Scaling factor: 10000
Parameter | Name:
C01225 | MCK: Ref. accelerations
Data type: INTEGER_32
Index: 23350
d
 = 5B36
h
Accelerations for reference search/homing
Homing
Setting range (min. value | unit | max. value)
0.0000 unit/s2 214748.3647
Subcodes Lenze setting Info
C01225/1 720.0000 unit/s2 MCK: Ref. initial acceleration
 • Starting acceleration for the starting speed ramps.
C01225/2 720.0000 unit/s2 MCK: Ref. search acceleration
 • Search acceleration for the search speed ramps.
; Read access ; Write access  CINH  PLC STOP  No transfer  COM  MOT Scaling factor: 10000
Parameter | Name:
C01226 | MCK: Ref. S-ramp times
Data type: UNSIGNED_16
Index: 23349
d
 = 5B35
h
S-ramp time for reference search/homing
 •Setting "0 s" ≡ no rounding
Homing
Setting range (min. value | unit | max. value)
0.000 s 10.000
Subcodes Lenze setting Info
C01226/1 0.000 s MCK: Ref. S-ramp time
 • S-ramp time for the starting and search speed ramps.
; Read access ; Write access  CINH  PLC STOP  No transfer  COM  MOT Scaling factor: 1000