Firmware 05.00 - DMS 4.2 EN - 02/2010 L 703
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00760
C00760
C00761
Parameter | Name:
C00760 | LA_SwitchPos: Analog connection list
Data type: UNSIGNED_16
Index: 23815
d
= 5D07
h
Connection parameters for "Switch-off positioning" application: 16-bi inputs
Selection of the 16-bit output signals for connection with the 16-bit input signals
The selection list contains all 16-bit output signals which can be assigned to the 16-bit inputs mapped by the
subcodes.
Selection list
See selection list - analog signals
Subcodes Lenze setting Info
C00760/1 0: Not connected LA_SwitchPos
: wCANDriveControl
C00760/2 0: Not connected LA_SwitchPos
: wMCIDriveControl
C00760/3 0: Not connected LA_SwitchPos
: nVoltageAdd_a
C00760/4 0: Not connected LA_SwitchPos
: nBoost_a
C00760/5 0: Not connected LA_SwitchPos
: nPWMAngleOffset
C00760/6 0: Not connected LA_SwitchPos
: nTorqueMotLim_a
C00760/7 0: Not connected LA_SwitchPos
: nTorqueGenLim_a
C00760/8 0: Not connected LA_SwitchPos
: nMainSetValue_a
C00760/9 0: Not connected LA_SwitchPos
: nAuxSetValue_a
C00760/10 0: Not connected LA_SwitchPos
: nGPAnalogSwitchIn1_a
C00760/11 0: Not connected LA_SwitchPos
: nGPAnalogSwitchIn2_a
C00760/12 0: Not connected LA_SwitchPos
: nGPArithmetikIn1_a
C00760/13 0: Not connected LA_SwitchPos
: nGPArithmetikIn2_a
C00760/14 0: Not connected LA_SwitchPos
: nGPMulDivIn_a
C00760/15 0: Not connected LA_SwitchPos
: nGPCompareIn1_a
C00760/16 0: Not connected LA_SwitchPos
: nGPCompareIn2_a
C00760/17 0: Not connected LA_SwitchPos
: wSMCtrl
C00760/18 0: Not connected LA_SwitchPos
: wReserved2
C00760/19 0: Not connected LA_SwitchPos
: wReserved3
C00760/20 0: Not connected LA_SwitchPos: wReserved4
C00760/21 0: Not connected LA_SwitchPos
: wReserved5
C00760/22 0: Not connected LA_SwitchPos
: wFreeIn1
C00760/23 0: Not connected LA_SwitchPos: wFreeIn2
C00760/24 0: Not connected LA_SwitchPos
: wFreeIn3
C00760/25 0: Not connected LA_SwitchPos
: wFreeIn4
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00761 | LA_SwitchPos: Digital connection list
Data type: UNSIGNED_16
Index: 23814
d
= 5D06
h
Connection parameters for "Switch-off positioning" application: Binary inputs
Selection of the binary output signals for connection with the binary input signals
The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the
subcodes.
Selection list
See selection list - digital signals
Subcodes Lenze setting Info
C00761/1 0: Not connected LA_SwitchPos
: bCInh
C00761/2 0: Not connected LA_SwitchPos
: bFailReset
C00761/3 0: Not connected LA_SwitchPos
: bSetQuickstop