8400 HighLine | Parameter setting & configuration
Technology applications
TA "Actuating drive speed"
274 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
7.4.3 Terminal assignment of the control modes
The following comparison provides information about which inputs/outputs of the application block LA_NCtrl are interconnected
to the digital and analog input/output terminals of the drive controller in the different control modes.
Control mode(C00007)
10: Terminals 0 12: Terminals 2 14: Terminals 11 16: Terminal 16 20: Keypad 21: PC 30: CAN 40: MCI
Digital input terminals
X5/RFR Controller enable/reset error
bFailReset
X5/DI1 Fixed setpoint 1/3
bJogSpeed1
Change of direction of
rotation
bSetSpeedCcw
Fixed setpoint 1/3
bJogSpeed1
- - Quick stop
bSetQuickstop
X5/DI2 Fixed setpoint 2/3
bJogSpeed2
Activate DC brake
bSetDCBrake
Fixed setpoint 2/3
bJogSpeed2
- -
X5/DI3 Activate DC brake
bSetDCBrake
Quick stop
bSetQuickstop
Motor potentiometer:
Increase speed
bMPotUp
CW rotation quick stop
bRLQCw
Manual homing in positive direction
bManJogPos
(in preparation)
X5/DI4 Change of direction of rotation
bSetSpeedCcw
Motor potentiometer:
Decrease speed
bMPotDown
CCW rotation quick stop
bRLQCcw
Manual homing in negative direction
bManJogNeg
(in preparation)
X5/DI5 ... DI7
- - - - - - - -
Analog input terminals
X3/A1U, A1I Main speed setpoint
nMainSetValue_a
10V ≡ 100% of reference speed (C00011
)
- - Additional speed setpoint
nAuxSetValue_a
10V ≡ 100% of reference speed (C00011
)
X3/A2U, A2I
- - - - - - - -
Digital output terminals
X4/DO1 Drive is ready to start
bDriveReady
X4/DO2 ... DO3
- - - - - - - -
X107/BD1, BD2
- - - - - - - -
X101/NO Fault
bDriveFail
Analog output terminals
X3/O1U Actual speed value
nMotorSpeedAct_a
10V ≡ 100% of reference speed (C00011
)
X3/O1I
- - - - - - - -
X3/O2U
X3/O2I
efesotomasyon.com - Lenze