8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01082
760 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
 
C01082
C01083
C01084
C01085
Parameter | Name:
C01082 | LS_WriteParamList: Execute mode
Data type: UNSIGNED_8
Index: 23493
d
 = 5BC5
h
As of version 04.00.00
LS_WriteParamList
 FB: Selection of the activation method
Selection list (Lenze setting printed in bold) Info
0by Execute
1 by Input Select The writing of the parameter list is activated by a FALSE/
TRUE edge at the bExecute input.
; Read access ; Write access  CINH  PLC STOP  No transfer  COM  MOT Scaling factor: 1
Parameter | Name:
C01083 | LS_WriteParamList: FailState
Data type: UNSIGNED_16
Index: 23492
d
 = 5BC4
h
As of version 04.00.00
LS_WriteParamList
 FB: Error status
Display range (min. value | unit | max. value)
0 34000
; Read access  Write access  CINH  PLC STOP ; No transfer  COM  MOT Scaling factor: 1
Parameter | Name:
C01084 | LS_WriteParamList: Error line
Data type: UNSIGNED_8
Index: 23491
d
 = 5BC3
h
As of version 04.00.00
LS_WriteParamList
 FB: Display of the number of the list entry at which the error occurred (in connection with the 
value set selected via bSelectWriteValue_1 and bSelectWriteValue_2).
Display range (min. value | unit | max. value)
0 16
; Read access  Write access  CINH  PLC STOP ; No transfer  COM  MOT Scaling factor: 1
Parameter | Name:
C01085 | LS_WriteParamList: Index
Data type: INTEGER_32
Index: 23490
d
 = 5BC2
h
As of version 04.00.00
LS_WriteParamList
 FB: Parameters for entries 1 ... 32
Setting range (min. value | unit | max. value)
0.000 16000.000
Subcodes Lenze setting Info
C01085/1 0.000 Parameter for entries 1 ... 32
 • Format: <code number>.<subcode number>
 • Examples: "12.000" = C00012; "26.001" = C00026/1
C01085/...
C01085/32
; Read access ; Write access  CINH  PLC STOP  No transfer  COM  MOT Scaling factor: 1000