8400 HighLine | Parameter setting & configuration
Motor control (MCTRL)
Monitoring
206 L Firmware 05.00 - DMS 4.2 EN - 02/2010
5.11.8 Maximum torque monitoring
This function extension is only available from version 04.00.00!
If the maximum possible torque C00057
is reached at the motor shaft, the response set in
C00608
will be carried out (Lenze setting: "0: No response").
If the activated monitoring is tripped:
The "OT1: Maximum torque reached
" error message will be output.
The bMctrlTorqueMax status output of the LS_DeviceMonitor
system block will be set
to TRUE.
Note!
In the Lenze setting (C00608 = "0: No response"), the maximum torque
monitoring is not
activated!