8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_AnalogSwitch_3
880 L Firmware 05.00 - DMS 4.2 EN - 02/2010
14.1.6 L_AnalogSwitch_3
This function block switches between two analog input signals. The switching is controlled
via a boolean input signal.
Inputs
Outputs
Identifier
Data type
Information/possible settings
nIn1_a
INT
Input signal 1
nIn2_a
INT
Input signal 2
bSet
BOOL
Selection of the input signal for the output to nOut_a
FALSE nIn1_a
TRUE nIn2_a
Identifier
Data type
Value/meaning
nOut_a
INT
Output signal
/B$QDORJ6ZLWFKB
Q,QBD
Q2XWBD
Q,QBD
E6HW