8400 HighLine | Parameter setting & configuration
Technology applications
TA "Table positioning"
312 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
7.5.3.6 PC
Connection Assignment Connection Assignment
X101/NC-NO LA_TabPos.bDriveFail
X5/RFR LA_TabPos.bFailReset X3/A1U -
X5/DI1 - X3/A1I -
X5/DI2 - X3/A2U -
X5/DI3 - X3/A2I -
X5/DI4 - X3/O1U LA_TabPos.nMotorSpeedAct_a
10V ≡ 100% of reference speed (C00011
)
X5/DI5 - X3/O1I
X5/DI6 - X3/O2U LA_TabPos.nMotorCurrent_a
10V ≡ 100% of I
max_mot
(C00022)
X5/DI7 - X3/O2I
X107/BD1 LA_TabPos.bMBrakeReleaseOut X4/DO1 LA_TabPos.bDriveReady
X107/BD2 - X4/DO2 LA_TabPos.bInTarget
X4/DO3 LA_TabPos.bHomePosAvailable
CG
CL
CH
X107 X4
24B 24O
GB DO1
BD2 DO3
GO
BD1 DO2
X1
+
M
+
==
X5
A2I
AR
COM
A1U
NC
A2U
A1I
NO
X3
DI3
DI2
DI4
DI5
DI6
DI7
GI
24I
DI1
RFR
GA
O1U
O1I
O2U
O2I
X101
24E
DriveFail
+
=
MBrakeReleaseOut
Controller enable
DriveReady
External
supply
24VDC
Actual speed value (V)
Actual speed value (I)
Actual motor current value (V)
Actual motor current value (I)
Load mechanicalsintarget position
Home position known
efesotomasyon.com - Lenze