EasyManua.ls Logo

Lenze E84AVHC Series - C00727 | Keypad digital values; C00728 | Keypad analog values

Lenze E84AVHC Series
1118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00726
702 L Firmware 05.00 - DMS 4.2 EN - 02/2010
C00726
C00727
C00728
C00750
Parameter | Name:
C00726 | Current limit values
Data type: UNSIGNED_8
Index: 23849
d
= 5D29
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00727 | Keypad digital values
Data type: UNSIGNED_8
Index: 23848
d
= 5D28
h
Executing control commands when operating via keypad
Setting range (min. value | unit | max. value)
01
Subcodes Lenze setting Info
C00727/1 0 "1" request quick stop
C00727/2 0 "1" request DC-injection braking
C00727/3 0 "1" request reversal
C00727/4 0 "1" request fixed speed setpoint 1
C00727/5 0 "1" request fixed speed setpoint 2
C00727/6 0 "1" motor potentiometer: request activation
C00727/7 0 "1" motor potentiometer: request pos. acceleration
C00727/8 0 "1" motor potentiometer: request neg. acceleration
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00728 | Keypad analog values
Data type: INTEGER_16
Index: 23847
d
= 5D27
h
Selection of different setpoints when operating via keypad
Setting range (min. value | unit | max. value)
-199.99 % 199.99
Subcodes Lenze setting Info
C00728/1 100.00 % Torque limit in motor mode
C00728/2 100.00 % Torque limit in generator mode
C00728/3 0.00 % Setpoint speed
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00750 | Select. of BU oscillos. channels
Data type: UNSIGNED_8
Index: 23825
d
= 5D11
h
This code is for device-internal use only and must not be written to by the user!