8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00272
634 L Firmware 05.00 - DMS 4.2 EN - 02/2010
C00272
C00273
C00274
C00275
C00276
C00280
Parameter | Name:
C00272 | SC: Depth - current setp. filter
Data type: UNSIGNED_16
Index: 24303
d
= 5EEF
h
Damping of the current setpoint filter for SC (servo control) mode
Setting range (min. value | unit | max. value) Lenze setting
0 db 100 0db
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT Scaling factor: 1
Parameter | Name:
C00273 | Moment of inertia
Data type: UNSIGNED_32
Index: 24302
d
= 5EEE
h
Moment of inertia for setpoint precontrol for SC (servo control) and SLVC (vector control) modes
Setting range (min. value | unit | max. value) Lenze setting
0.00 kg cm^2 600000.00 0.00 kg cm^2
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT Scaling factor: 100
Parameter | Name:
C00274 | SC: Max. acceleration change
Data type: UNSIGNED_16
Index: 24301
d
= 5EED
h
Limitation of acceleration change for SC (servo control) mode
Setting in % of M_Nenn per ms.
Setting range (min. value | unit | max. value) Lenze setting
0.0 %/ms 400.0 400.0 %/ms
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT Scaling factor: 10
Parameter | Name:
C00275 | Setpoint precontrol filtering
Data type: UNSIGNED_16
Index: 24300
d
= 5EEC
h
As of version 02.00.00
Filter time of the setpoint precontrol for SC (servo control) and SLVC (vector control) modes
The setpoint precontrol requires the entry of the moment of inertia in C00273
.
Setting range (min. value | unit | max. value) Lenze setting
0.0 ms 1000.0 1.0 ms
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT Scaling factor: 10
Parameter | Name:
C00276 | SC: Max. output voltage
Data type: UNSIGNED_8
Index: 24299
d
= 5EEB
h
As of version 02.00.00
Maximum output voltage at SC operating mode (servo control)
Regarding the current DC-bus voltage.
Setting range (min. value | unit | max. value) Lenze setting
80 % 99 95 %
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT Scaling factor: 1
Parameter | Name:
C00280 | SC: Filter time const. DC detect.
Data type: UNSIGNED_16
Index: 24295
d
= 5EE7
h
Filter time constant for DC-bus voltage filtering
The filter time constant is e.g. used for the field weakening control for SC (servo control) mode.
Setting range (min. value | unit | max. value) Lenze setting
1 ms 1000 25 ms
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1