8400 HighLine | Parameter setting & configuration
Diagnostics & error management
Error messages of the operating system
482 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
ID1: Motor data identification error [xx.0123.00057]
ID3: CINH Motor data identification [xx.0123.00058]
ID4: Resistance identification error [xx.0123.00059]
OC12: I2xt overload - brake resistor [xx.0123.00065]
OC11: Clamp operation active [xx.0123.00071]
Response (Lenze setting printed in bold)
None Fault Trouble TroubleQuickstop Warning : WarningLocked Information
Cause Remedy
The device has detected an error during the motor data
identification.
Possible causes:
• Interrupted motor cable.
• Switched-off power section during the identification.
• Implausible start parameter settings.
• Check the motor connections and the corresponding
plug connector on the device and, if necessary, the
motor terminal box.
• Correct start parameters for the motor parameter
identification (motor nameplate data).
• Stable power supply of the device.
Response (Lenze setting printed in bold)
None Fault Trouble TroubleQuickstop Warning : WarningLocked Information
Cause Remedy
The device has detected controller inhibit during the
motor data identification.
• This cancels the identification process. The Lenze
setting of the motor data is used.
• Do not set controller inhibit during the motor data
identification.
• Do not execute any device function which may
activate controller inhibit.
Response (Lenze setting printed in bold)
None Fault Trouble TroubleQuickstop : Warning WarningLocked Information
Cause Remedy
The device has recognised that an error has occurred in
the calculation of the motor cable resistance.
• The parameters for cable cross-section and cable
length are implausible.
Enter sensible values for cable cross-section and motor
cable length.
Response (Lenze setting printed in bold)
None : Fault Trouble TroubleQuickstop Warning WarningLocked Information
Cause Remedy
Too frequent and too long braking processes. • Check drive dimensioning.
• Check parameterisation (C00129
, C00130, C00131).
Response (Lenze setting printed in bold)
None Fault Trouble TroubleQuickstop : Warning WarningLocked Information
Cause Remedy
The device indicates that the "CLAMP" overcurrent
limitation has been activated.
• A permanent clamp operation causes an overload
disconnection.
Reduce setpoint generation dynamics or motor load.
efesotomasyon.com - Lenze