Firmware 05.00 - DMS 4.2 EN - 02/2010 L 579
8400 HighLine | Parameter setting & configuration
Parameter reference
Structure of the parameter descriptions
12.1 Structure of the parameter descriptions
Each parameter is described in the Parameter list
in the form of a table which consists of
the following three areas:
Table header
The table header contains the following general information:
Parameter number (Cxxxxx)
Parameter name (display text in the »Engineer» and keypad)
Data type
Parameter index in decimal and hexadecimal notation for access via a fieldbus (e.g.
CAN system bus).
Tip!
The parameter index is calculated as follows:
Index [dec] = 24575 - code
Index [hex] = 0x5FFF - code
Example for code C00005:
Index [dec] = 24575 - 5 = 24570
Index [hex] = 0x5FFF - 0x{5} = 0x5FFA
Table contents
The table contains further general explanations & notes on the parameter and the possible
settings, which are represented in different ways depending on the parameter type:
Parameters with read-only access
Parameters with write access
Table footer
The table footer contains the Parameter attributes
.