8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01091
762 L Firmware 05.00 - DMS 4.2 EN - 02/2010
C01091
C01092
Parameter | Name:
C01091 | LS_ParReadWrite 1-6: Cycle time
Data type: UNSIGNED_16
Index: 23484
d
= 5BBC
h
As of version 04.00.00
Time interval for cyclic reading/writing
Selection list
0 0 (by Execute)
20 20 ms
50 50 ms
100 100 ms
200 200 ms
500 500 ms
1000 1 s
2000 2 s
5000 5 s
10000 10 s
Subcodes Lenze setting Info
C01091/1 0: 0 (by Execute) LS_ParReadWrite_1
: Cycle time
C01091/2 0: 0 (by Execute) LS_ParReadWrite_2
: Cycle time
C01091/3 0: 0 (by Execute) LS_ParReadWrite_3
: Cycle time
C01091/4 0: 0 (by Execute) LS_ParReadWrite_4
: Cycle time
C01091/5 0: 0 (by Execute) LS_ParReadWrite_5
: Cycle time
C01091/6 0: 0 (by Execute) LS_ParReadWrite_6
: Cycle time
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01092 | LS_ParReadWrite 1-6: FailState
Data type: UNSIGNED_16
Index: 23483
d
= 5BBB
h
As of version 04.00.00
Error status
Display range (min. value | unit | max. value)
0 34000
Subcodes Info
C01092/1 LS_ParReadWrite_1: FailState
C01092/2 LS_ParReadWrite_2
: FailState
C01092/3 LS_ParReadWrite_3
: FailState
C01092/4 LS_ParReadWrite_4: FailState
C01092/5 LS_ParReadWrite_5
: FailState
C01092/6 LS_ParReadWrite_6
: FailState
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1