8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_RSFlipFlop_2
1046 L Firmware 05.00 - DMS 4.2 EN - 02/2010
14.1.124 L_RSFlipFlop_2
The functionality of this FB corresponds to that of an RS flipflop:
An input signal at bSet serves to set the bOut output permanently.
An input signal at bReset serves to reset the output.
Additional, inverted output bNegOut
Inputs
Outputs
Identifier
Data type
Information/possible settings
bSet
BOOL
Setting input
TRUE The bOut output is set to TRUE.
•The bNegOut output is set to FALSE.
bReset
BOOL
Reset input
TRUE The bOut output is set to FALSE.
•The bNegOut output is set to TRUE.
Identifier
Data type
Value/meaning
bOut
BOOL
Output signal
bNegOut
BOOL
Output signal, inverted
/B56)OLS)ORSB
E5HVHW
E6HW
5
6
E2XW
E1HJ2XW