EasyManua.ls Logo

Lenze E84AVHC Series - C00823 | L_DigitalLogic_2: Truth table; C00824 | L_DigitalLogic5_1: Function

Lenze E84AVHC Series
1118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 05.00 - DMS 4.2 EN - 02/2010 L 709
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00823
C00823
C00824
Parameter | Name:
C00823 | L_DigitalLogic_2: Truth table
Data type: UNSIGNED_8
Index: 23752
d
= 5CC8
h
FB L_DigitalLogic_2: Parameterisation of the truth table
Selection list
0False
1True
Subcodes Lenze setting Info
C00823/1 0: FALSE bOut for bIn1=0 / bIn2=0 / bIn3=0
C00823/2 0: FALSE bOut for bIn1=1 / bIn2=0 / bIn3=0
C00823/3 0: FALSE bOut for bIn1=0 / bIn2=1 / bIn3=0
C00823/4 0: FALSE bOut for bIn1=1 / bIn2=1 / bIn3=0
C00823/5 0: FALSE bOut for bIn1=0 / bIn2=0 / bIn3=1
C00823/6 0: FALSE bOut for bIn1=1 / bIn2=0 / bIn3=1
C00823/7 0: FALSE bOut for bIn1=0 / bIn2=1 / bIn3=1
C00823/8 0: FALSE bOut for bIn1=1 / bIn2=1 / bIn3=1
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00824 | L_DigitalLogic5_1: Function
Data type: UNSIGNED_8
Index: 23751
d
= 5CC7
h
FB L_DigitalLogic5_1: Selection of the internal logic interconnection
Selection list (Lenze setting printed in bold) Info
0bOut = 0
1bOut = 1
2 bOut = f (truth table) The truth table parameterised in C00825
is used.
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1