8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00204
628 L Firmware 05.00 - DMS 4.2 EN - 02/2010
C00204
C00205
C00206
C00210
C00220
C00221
C00222
Parameter | Name:
C00204 | Serial number
Data type: VISIBLE_STRING
Index: 24371
d
= 5F33
h
Display of the single device component serial numbers
Subcodes Info
C00204/1 Serial no.: Control card
C00204/2 Serial no.: Power section
C00204/3 Serial no.: MCI module
C00204/4 Reserved
C00204/5 Serial no.: Memory module
C00204/6 Serial no.: Safety card
C00204/7 Serial no.: Standard device
C00204/8 Serial no.: Complete device
C00204/9 Reserved
; Read access Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00205 | Info
Data type: VISIBLE_STRING
Index: 24370
d
= 5F32
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00206 | Production date
Data type: VISIBLE_STRING
Index: 24369
d
= 5F31
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00210 | HW version
Data type: VISIBLE_STRING
Index: 24365
d
= 5F2D
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00220 | Accel. time - add. setpoint
Data type: UNSIGNED_32
Index: 24355
d
= 5F23
h
FB L_NSet_1: Acceleration time for the additional setpoint nNAdd_a
Setting range (min. value | unit | max. value) Lenze setting
0.000 s 999.999 0.000 s
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000
Parameter | Name:
C00221 | Decel. time - add. setpoint
Data type: UNSIGNED_32
Index: 24354
d
= 5F22
h
FB L_NSet_1: Deceleration time for the additional setpoint nNAdd_a
Setting range (min. value | unit | max. value) Lenze setting
0.000 s 999.999 0.000 s
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000
Parameter | Name:
C00222 | L_PCTRL_1: Vp
Data type: INTEGER_16
Index: 24353
d
= 5F21
h
FB L_PCTRL_1: Gain factor Vp for the PID process controller
Setting range (min. value | unit | max. value) Lenze setting
0.1 500.0 1.0
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10