Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 187
8400 HighLine | Parameter setting & configuration
Motor control (MCTRL)
Encoder/feedback system
5.9.3 Encoder with HTL level at DI1/DI2
Low speeds (except for edge counting)
For the first three methods (C00496
= 0, 1, or 2), the minimum speed that can be measured
depends on the number of increments of the encoder.
The quantisation error
is independent of the encoder PPR.
exclusively depends on the encoder quality (encoder errors).
is minimally 0.5 rpm.
For a maximum dynamic performance, the scan time is automatically kept at the
minimum value required through internal arithmetic operations.
Note!
At the digital terminals DI1 and DI2, only encoders with HTL level can be used.
In spite of the selected operating mode without
encoder feedback, the actual
speed value (C00051
) is calculated if an encoder is connected and "1: Encoder
signal FrqIn12" is selected in C00495
.
Number of encoder increments
C00420/1
Minimum speed [rpm]
816
16 8
32 4
64 2
128 1
256 0.5
≥ 512 0.25
efesotomasyon.com - Lenze