8400 HighLine | Parameter setting & configuration
Diagnostics & error management
Logbook
460 L Firmware 05.00 - DMS 4.2 EN - 02/2010
9.5 Logbook
The integrated logbook function of the controller chronologically logs important events
within the system and plays an important role for troubleshooting and controller
diagnostics.
Events that can be logged
The following events can be logged in the logbook:
Error messages of the operating system
( 471)
Error messages generated by the application (via LS_SetError
)
Loading/saving of parameter sets, loading of the Lenze setting (in preparation)
Transmitting the firmware to the controller (in preparation)
Switching on/off of the controller
Information saved
For each event, the following information is saved in the logbook:
Type of response to the event (e.g. fault, warning or information)
Subject area that activated the event (e.g. CAN or USER).
Event
Value of power-on time meter
Selected process values (analog % signals, binary signals)
Memory depth
Maximum number of logbook entries: 14 (extension in preparation)
efesotomasyon.com - Lenze

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze E84AVHC Series and is the answer not in the manual?

Lenze E84AVHC Series Specifications

General IconGeneral
BrandLenze
ModelE84AVHC Series
CategoryInverter Drive
LanguageEnglish

Related product manuals