8400 HighLine | Parameter setting & configuration
Basic drive functions (MCK)
Homing
396 L Firmware 05.00 - DMS 4.2 EN - 02/2010
8.6.1 Parameter setting
Parameterisation dialog in the »Engineer«
Short overview of parameters for "Referencing" operating mode:
Parameter Info Lenze setting
Value Unit
C01221 MCK: Ref. mode 12: >_Lp
C01224/1
MCK: Ref. initial speed 720.0000 unit/s
C01225/1
MCK: Ref. initial acceleration 720.0000 unit/s2
C01224/2
MCK: Ref. search speed 180.0000 unit/s
C01225/2
MCK: Ref. search acceleration 720.0000 unit/s2
C01226/1
MCK: Ref. S-ramp time 0.000 s
C01222
MCK: Ref. M limit mode 14/15 10.00 %
C01223
MCK: Ref. waiting time mode 14/15 100 ms
C01227/1
MCK: Ref. offset reference degree 0.0000 unit
C01227/2
MCK: Ref. home position 0.0000 unit
C01228
MCK: Ref. sequence profile 0
C01229/1
MCK: Positive SW limit position 0.0000 units
C01229/2
MCK: Negative SW limit position 0.0000 units