Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 751
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00917
C00917
C00922
C00940
C00941
Parameter | Name:
C00917 | Motor cable resistance
Data type: UNSIGNED_16
Index: 23658
d
= 5C6A
h
Display of the motor cable resistance of a motor cable phase
• The motor cable resistance is calculated based on the motor cable length set in C00915
and the motor cable
cross-section set in C00916
.
Display range (min. value | unit | max. value)
0 mOhm 64000
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00922 | ICM_DiagnosticCounter
Data type: UNSIGNED_16
Index: 23653
d
= 5C65
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00940 | L_ConvW numerator
Data type: INTEGER_16
Index: 23635
d
= 5C53
h
As of version 04.00.00
Setting range (min. value | unit | max. value)
-32767 32767
Subcodes Lenze setting Info
C00940/1 1 L_ConvW_1
: Nominator
C00940/2 1 L_ConvW_2
: Nominator
C00940/3 1 L_ConvW_3
: Nominator
C00940/4 1 L_ConvW_4
: Nominator
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00941 | L_ConvW denominator
Data type: INTEGER_16
Index: 23634
d
= 5C52
h
As of version 04.00.00
Setting range (min. value | unit | max. value)
1 32767
Subcodes Lenze setting Info
C00941/1 1 L_ConvW_1: Denominator
C00941/2 1 L_ConvW_2
: Denominator
C00941/3 1 L_ConvW_3
: Denominator
C00941/4 1 L_ConvW_4: Denominator
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1