EasyManua.ls Logo

Lenze E84AVHC Series - 7.7.6 Analog comparison; 7.7.7 Binary signal monitor

Lenze E84AVHC Series
1118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8400 HighLine | Parameter setting & configuration
Technology applications
"GeneralPurpose" functions
358 L Firmware 05.00 - DMS 4.2 EN - 02/2010
7.7.6 Analog comparison
This function compares two analog signals and can be used e.g. to realise a trigger. The
comparison operation, hysteresis and window size can be parameterised.
[7-6] GeneralPurpose function "Analog comparison"
For a detailed functional description see FB L_Compare.
7.7.7 Binary signal monitor
This function serves to output four binary signals selected from a list of all binary output
signals available in the drive controller. You can set an inversion of the output signals.
[7-7] GeneralPurpose function "Binary signal monitor"
For a detailed functional description see FB L_SignalMonitor_b.
bGPCompareOut
nGPCompareIn1_a
nGPCompareIn2_a
f
=
C00680
C00682C00681
C00830/16
C00830/17
Parameter Info Lenze setting
Value Unit
C00680 L_Compare_1: Fct. 6: |In1| < |In2|
C00681
L_Compare_1: Hysteresis 0.50 %
C00682
L_Compare_1: Window 2.00 %
bGPSignalOut1
C00411/1 C00412 - Bit 0
0
1
C00411/2
C00411/3
C00411/4
bGPSignalOut2
C00412 - Bit 1
0
1
bGPSignalOut3
C00412 - Bit 2
0
1
bGPSignalOut4
C00412 - Bit 3
0
1
Parameter Info Lenze setting
Value Unit
C00411/1...4 L_SignalMonitor_b: Signal 1 ... 4 0: Not connected
C00412
L_SignalMonitor_b: Inversion Bit coded
efesotomasyon.com - Lenze

Table of Contents

Related product manuals