8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00006
588 L Firmware 05.00 - DMS 4.2 EN - 02/2010
C00006
Parameter | Name:
C00006 | Select motor control
Data type: UNSIGNED_8
Index: 24569
d
= 5FF9
h
Selection of the motor control mode (operating mode)
Motor control (MCTRL)
: Selection of control mode
Selection list (Lenze setting printed in bold) Info
2 SC: Servo control ASM This control type is used for the servo control of an
asynchronous motor.
The control type requires a speed feedback via an
encoder mounted to the motor!
4 SLVC: Vector control This control type is used for sensorless vector control of
an asynchronous motor.
The control type requires motor parameters to be set
as exactly as possible!
6 VFCplus: V/f linear This control type is used for the speed control of an
asynchronous motor via a linear V/f characteristic and is
the simplest control type.
For setting the V/f characteristic, only the rated
frequency (C00089
) and the rated voltage (C00090) of
the motor have to be entered.
7 VFCplus: V/f linear + encoder This control type is used for speed control of an
asynchronous motor via a linear V/f characteristic.
The control type requires a speed feedback via an
encoder mounted to the motor!
For setting the V/f characteristic, only the rated
frequency (C00089
) and the rated voltage (C00090) of
the motor have to be entered.
8 VFCplus: V/f quadr This control type is used for speed control of an
asynchronous motor via a square-law V/f characteristic.
For setting the V/f characteristic, only the rated
frequency (C00089
) and the rated voltage (C00090) of
the motor have to be entered.
9 VFCplus: V/f quadr + encoder This control type is used for speed control of an
asynchronous motor via a square-law V/f characteristic.
The control type requires a speed feedback via an
encoder mounted to the motor!
For setting the V/f characteristic, only the rated
frequency (C00089
) and the rated voltage (C00090) of
the motor have to be entered.
10 VFCplus: V/f definable As of version 04.00.00
This type of control is used for the speed control of an
asynchronous motor via a user-definable characteristic
with several interpolation points.
For setting the V/f characteristic, only the rated
frequency (C00089
) and the rated voltage (C00090) of
the motor have to be entered.
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1