Firmware 05.00 - DMS 4.2 EN - 02/2010 L 27
8400 HighLine | Parameter setting & configuration
Introduction: Parameterising the controller
General notes on parameters
2.1 General notes on parameters
All parameters for controller parameterising or monitoring are saved as so-called "codes".
The codes are numbered and indicated by the prefix "C" before the code, e.g. "C00002".
In addition, every code has a name and specific attributes:
Access type (read, write)
–Data type
Limit values
Lenze setting (factory-set scaling)
For the sake of clarity, some codes contain "subcodes" for saving parameters. This
Manual uses a slash "/" as a separator between code and subcode, e.g. C00118/3".
According to their functionality, the parameters are divided into three groups:
Tip!
The terms "code" and "subcode" generally correspond to the terms "index" and
"subindex" and "parameter" and "subparameter".
2.2 Handling the memory module
All parameters of the drive system are saved in the integrated memory module of the
controller. These include
the parameters of the controller
the parameters of the communication module plugged into the MCI interface
the parameters of the possibly existing safety module (device variant)
When handling the memory module, a distinction is drawn between the following
scenarios:
Parameter group Examples
Setting parameters
Parameters for specifying setpoints and for setting device /
monitoring functions.
C00005
: Application selection
C00012
: Acceleration time - main setpoint
C00169
: Logbook setting
C00604
: Resp. to device overload (Ixt)
Configuration parameters
Parameters for configuring signal connections (function
block interconnections) within the device, e.g. assignment of
the digital input terminals to the control inputs of the
technology application.
C00700
: LA_NCtrl: Analog connection list
C00701
: LA_NCtrl: Digital connection list
C00710
: LA_TabPos: Analog connection list
C00711
: LA_TabPos: Digital connection list
Diagnostic/Display parameters
Parameters for displaying device-internal process factors,
current actual values, and status messages, e.g. for
diagnostic purposes. These are read-only parameters.
C00052
: Motor voltage
C00137
: Device state
C00150
: Status word
C00165
: Error information
efesotomasyon.com - Lenze