Firmware 05.00 - DMS 4.2 EN - 02/2010 L 1049
8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_SignalMonitor_a
14.1.127 L_SignalMonitor_a
This FB outputs four analog signals which can be selected from a list of analog output
signals of all function blocks provided in the device.
Offset and gain of the source signals are adjustable.
Outputs
Parameter
Identifier
Data type
Value/meaning
nOut1_a
INT
Output signal
Internal limitation to ±32767
nOut2_a
INT
Output signal
Internal limitation to ±32767
nOut3_a
INT
Output signal
Internal limitation to ±32767
nOut4_a
INT
Output signal
Internal limitation to ±32767
Parameter Possible settings Info
C00410/1
...
C00410/4
Selection of the signal sources for
nOut1_a ... nOut4_a
0Not connected
1000 LA_nCtrl_wDriveControlStatus
1001 LA_nCtrl_wFailNumber
1002 LA_nCtrl_nMotorCurrent_a
... ...
42017 LA_nCtrl_In_nPIDSerValue_a
C00413/1
C00413/3
C00413/5
C00413/7
-199.99 % +199.99 Offset
C00413/2
C00413/4
C00413/6
C00413/8
-199.99 % +199.99 Gain
/B6LJQDO0RQLWRUBD
Q2XWBD
& &&
Q2XWBD
& &&
Q2XWBD
& &&
Q2XWBD
& &&