8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01010
758 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
C01010
C01020
C01021
C01022
Parameter | Name:
C01010 | L_ArithmetikPhi 1-3: Function
Data type: UNSIGNED_8
Index: 23565
d
= 5C0D
h
Selection of the internal arithmetics
Selection list
0 dnOut_p = dnIn1_p
1 dnOut_p = dnIn1_p + dnIn2_p
2 dnOut_p = dnIn1_p - dnIn2_p
3 dnOut_p = dnIn1_p * dnIn2_p
4 dnOut_p = dnIn1_p / dnIn2_p
Subcodes Lenze setting Info
C01010/1 0: dnOut_p = dnIn1_p L_ArithmetikPhi_1
: Function
C01010/2 0: dnOut_p = dnIn1_p L_ArithmetikPhi_2
: Function
C01010/3 0: dnOut_p = dnIn1_p L_ArithmetikPhi_3
: Function
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01020 | L_Odometer_1: Storage capacity
Data type: UNSIGNED_8
Index: 23555
d
= 5C03
h
As of version 04.00.00
L_Odometer_1
FB: Number of measurements
Selection list (Lenze setting printed in bold)
1 1 measurement
2 2 measurements
3 3 measurements
4 4 measurements
5 5 measurements
6 6 measurements
77 measurements
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01021 | L_Odometer_1: Type of storage
Data type: UNSIGNED_8
Index: 23554
d
= 5C02
h
As of version 04.00.00
L_Odometer_1
FB: If "Ring buffer" is selected, the measurement will start all over again after the number of
measurements selected in C01020 has been performed and the old values will be overwritten. Otherwise, the
measurement will stop.
Selection list (Lenze setting printed in bold)
0 No ring buffer
1 Ring buffer
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C01022 | L_Odometer_1: Input selection
Data type: UNSIGNED_8
Index: 23553
d
= 5C01
h
As of version 04.00.00
L_Odometer_1
FB: Selection of position or speed input
Selection list (Lenze setting printed in bold)
0 Pos input
1V input
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1