8400 HighLine | Parameter setting & configuration
Technology applications
TA "Switch-off positioning"
348 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
7.6.3.8 MCI
Connection Assignment Connection Assignment
X101/NC-NO -
X5/RFR LA_SwitchPos: bFailReset X3/A1U LA_SwitchPos.nAuxSetValue_a
10V ≡ 100% of reference speed (C00011
)
X5/DI1 LA_SwitchPos: bJogCtrlStop1 X3/A1I
X5/DI2 LA_SwitchPos: bJogCtrlSlowDown1 X3/A2U -
X5/DI3 LA_SwitchPos: bJogCtrlStop2 X3/A2I -
X5/DI4 LA_SwitchPos: bJogCtrlSlowDown2 X3/O1U -
X5/DI5 LA_SwitchPos: bJogCtrlStop3 X3/O1I -
X5/DI6 LA_SwitchPos: bJogCtrlSlowDown3 X3/O2U -
X5/DI7 - X3/O2I -
X107/BD1 LA_SwitchPos.bMBrakeReleaseOut X4/DO1 -
X107/BD2 - X4/DO2 -
X4/DO3 -
X107 X4
24B 24O
GB DO1
BD2 DO3
GO
BD1 DO2
+
M
X5
A2I
AR
COM
A1U
NC
A2U
A1I
NO
X3
DI3
DI2
DI4
DI5
DI6
DI7
GI
24I
DI1
RFR
GA
O1U
O1I
O2U
O2I
X101
24E
+
==
CG
CL
CH
X1
Mci1_In
Mci1_Out
Mci2/3_In/Out
MciDriveControl
MainSetValue
DriveControlStatus
MotorSpeedAct
nGPSignalOut1_a
+
=
Speed
setpoint
Controller enable / reset error
External 24 V
DC supply
Stop function 1
Selection: Pre-switch off 1
Stop function 2
Selection: Pre-switch off 2
Stop function 3
Selection: Pre-switch off 3
Brake released