Firmware 05.00 - DMS 4.2 EN - 02/2010 L 467
8400 HighLine | Parameter setting & configuration
Diagnostics & error management
Monitoring
9.6.3 AutoFailReset function
The AutoFailReset function serves to automatically reset the latching "Fault" and
"TroubleQSP" errors as well as the latching "WarningLocked" warning.
The "latching" term means that the effect on the controller remains active even after the
error cause has been removed.
To reset latching errors and warnings, the following options are available:
Manual reset
with device command C00002/19
(active by LOW/HIGH edge)
by a LOW/HIGH edge at the bResetFail input of the LS_DriveInterface
system block
(the "FailReset" control bit in the control word must be parameterised with a value
of "1").
Automatic reset
using the AutoFailReset function.
Overview of the relevant parameters
Parameter Info
C00184
Repetition time of the error reset processes
C00185 Time left until the next error reset process
C00186
Max. number of error reset processes
C00187 Current number of error reset processes carried out ineffectively
C00188
Configuration of the AutoFailReset function
•0: Off
•1: Fault + TroubleQSP
•2: WarningLocked
3: All locking
C00189
Response after max. number of error reset processes has been reached
Highlighted in grey = display parameter
efesotomasyon.com - Lenze

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze E84AVHC Series and is the answer not in the manual?

Lenze E84AVHC Series Specifications

General IconGeneral
BrandLenze
ModelE84AVHC Series
CategoryInverter Drive
LanguageEnglish

Related product manuals