8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_PhaseIntK_1
1028 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
14.1.115.1 Function at constant input value
Selection: C01150
= "0: Loading with level" or "1: Loading with edge"
[14-37] Switching performance if the overflow is in the positive direction
If "0: Loading with level" is selected in C01150, the bLoad input is status-controlled: In
case of a TRUE signal, the integrator is loaded with the value at dnSet_p and the bStatus
output is set to FALSE.
If "1: Loading with edge" is selected in C01150
, the bLoad input is edge-controlled: In
case of a FALSE/TRUE edge, the integrator is loaded with the value at dnSet_p and then
immediately continues to integrate, the bStatus output is set to FALSE.
A positive signal at nIn_v is incremented (the counter content is increased with every
function call).
A negative signal at nIn_v is decremented (the counter content is reduced with every
function call).
dnOut_p outputs the counter content of the bipolar integrator.
– If the counter content exceeds a value of +32767 encoder revolutions (corresponds
to +2147483647 incr.), an overflow occurs and the counting process continues at a
value of -32768 encoder revolutions.
– If the counter content falls below a value of -32768 encoder revolutions (corresponds
to -2147483648 incr.), an overflow occurs and the counting process starts at a value
of +32767 encoder revolutions.
bStatus will be set to TRUE if the comparison value set in C01151/x
is reached.
n Overflow at ±2147483648 incr. (±32767 encoder revolutions)
o C01151/x
: Comparison value (is valid for both the positive and the negative value range)
dnOut_p
t
0
TRUE
FALSE
bStatus
t