8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_ConvW_3
926 L Firmware 05.00 - DMS 4.2 EN - 02/2010
14.1.43 L_ConvW_3
This FB serves to convert analog signal forms. The following conversions per parameter can
be selected:
[%] [incr/ms]
[incr/ms] [%]
Conversion via parameterisable factors
Input signal is passed through without conversion
Inputs
Outputs
Parameter
Identifier
Data type
Information/possible settings
wIn
WORD
Input signal
Identifier
Data type
Value/meaning
wOut
WORD
Output signal
Parameter Possible settings Info
C00940/3
-2147483647 2147483647 Numerator
Lenze setting: 1
C00941/3
-2147483647 2147483647 Denominator
Lenze setting: 1
C00942/3
Selection of the conversion
0 wOut = wIn (no conversion)
1[%] [incr/ms]
2[incr/ms] [%]
3 wOut = wIn * C00940
/ C00941
For conversion formulae see L_ConvW_1.