8400 HighLine | Parameter setting & configuration
Device control (DCTRL)
Controller commands
74 L Firmware 05.00 - DMS 4.2 EN - 02/2010
4.1.6 Reset error
The C00002/19
= "1: On / start" controller command acknowledges an existing error
message if the error cause has been eliminated and thus the error is not pending anymore.
After resetting the current error, further errors may be pending which must be reset as
well.
The status-determining error is displayed in C00168
.
The current error is displayed in C00170
.
Tip!
An error message can also be acknowledged by activating the Reset error button in
the Diagnostics tab.
Detailed information on error messages can be found in the "Diagnostics & error
management" chapter. ( 452)
4.1.7 Delete logbook
The C00002/21
= "1: On / start" controller command deletes all logbook entries.
Tip!
Click the Logbook button in the Diagnostics tab to display the logbook in the
»Engineer«.
In the Logbook dialog box, it is also possible to delete all logbook entries by clicking
the Delete button.
Detailed information on the logbook can be found in the "Diagnostics & error
management" chapter. ( 452)