8400 HighLine | Parameter setting & configuration
Diagnostics & error management
Monitoring
466 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
9.6.2 Setting the error response
When a monitoring function responds, the response set for this monitoring function
(TroubleQSP, Warning, Fault, etc.) will be triggered.
For many monitoring functions the response can be individually parameterised via
parameters.
Tip!
The table in chapter "Short overview (A-Z)
" contains the error messages for which
the response can be set .
( 475)
Warning thresholds
Some of the monitoring functions are activated if a defined warning threshold (e.g.
temperature) has been exceeded.
The corresponding preset threshold values can be changed via the following
parameters:
Parameter Info
C00120
Motor overload threshold (I²xt)
C00123
Device utilisat. threshold (Ixt)
C00572
Brake resistor overload threshold
C00599
Motor phase failure threshold