Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 793
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02611
 
C02611
Parameter | Name:
C02611 | MCK: Limitations
Data type: INTEGER_16
Index: 21964
d
 = 55CC
h
Speed setpoint limits for the determination of limited validity ranges
Note:
Traversing with setpoints through arising blocking zones takes place along the ramp set in C02610/2
.
Min/Max speed
Setting range (min. value | unit | max. value)
0.00 % 199.99
Subcodes Lenze setting Info
C02611/1 199.99 % MCK: Pos. max. speed
 • Upper limit of the speed setpoint limitation in 
positive direction of rotation.
C02611/2 0.00 % MCK: Pos. min. speed
 • Lower limit of the speed setpoint limitation in 
positive direction of rotation.
C02611/3 0.00 % MCK: Neg. min. speed
 • Lower limit of the speed setpoint limitation in 
negative direction of rotation.
C01210/4 199.99 % MCK: Neg. max. speed
 • Upper limit of the speed setpoint limitation in 
negative direction of rotation.