EasyManua.ls Logo

Lenze E84AVHC Series - 14.1.8 L_AnalogSwitch_5

Lenze E84AVHC Series
1118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_AnalogSwitch_5
882 L Firmware 05.00 - DMS 4.2 EN - 02/2010
14.1.8 L_AnalogSwitch_5
This function block switches between two analog input signals. The switching is controlled
via a boolean input signal.
Inputs
Outputs
Identifier
Data type
Information/possible settings
nIn1_a
INT
Input signal 1
nIn2_a
INT
Input signal 2
bSet
BOOL
Selection of the input signal for the output to nOut_a
FALSE nIn1_a
TRUE nIn2_a
Identifier
Data type
Value/meaning
nOut_a
INT
Output signal
/B$QDORJ6ZLWFKB
Q,QBD
Q2XWBD
Q,QBD
E6HW
efesotomasyon.com - Lenze

Table of Contents

Related product manuals