Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 287
8400 HighLine | Parameter setting & configuration
Technology applications
TA "Actuating drive speed"
7.4.4 Setting parameters (short overview)
Parameter Info Lenze setting
Value Unit
C00012 Accel. time - main setpoint 2.000 s
C00013
Decel. time - main setpoint 2.000 s
C00019
Auto-DCB: Threshold 3 rpm
C00024
Comparison value N_Act 0.00 %
C00036
DCB: Current 50.00 %
C00039/1
Fixed setpoint 1 40.00 %
C00039/2
Fixed setpoint 2 60.00 %
C00039/3
Fixed setpoint 3 80.00 %
C00039/4...15
Fixed setpoint 4 ... 15 0.00 %
C00101/1...15
Additional acceleration time 1 ... 15 0.000 s
C00103/1...15
Additional deceleration time 1 ... 15 0.000 s
C00105
Deceleration time - quick stop 2.000 s
C00106
Auto-DCB: Hold time 0.500 s
C00107
DCB: Hold time 999.000 s
C00134
Ramp rounding - main setpoint 0: Off
C00182
S-ramp time PT1 20.00 s
C00190
Setpoint arithmetic 0: NOut = NSet
C00220
Accel. time - add. setpoint 0.000 s
C00221
Decel. time - add. setpoint 0.000 s
C00222
L_PCTRL_1: Vp 1.0
C00223
L_PCTRL_1: Tn 400 ms
C00224
L_PCTRL_1: Kd 0.0
C00225
L_PCTRL_1: MaxLimit 199.99 %
C00226
L_PCTRL_1: MinLimit -199.99 %
C00227
L_PCTRL_1: Acceleration time 0.010 s
C00228 L_PCTRL_1: Deceleration time 0.010 s
C00233
L_PCTRL_1: Root function 0: Off
C00241
L_NSet_1: Hyst. NSet reached 0.50 %
C00242 L_PCTRL_1: Operating mode 0: Off
C00243
L_PCTRL_1: Accel. time influence 5.000 s
C00013
L_PCTRL_1: Decel. time influence 5.000 s
C00632/1
L_NSet_1: Blocking speed 1 max 0.00 %
C00632/2
L_NSet_1: Blocking speed 2 max 0.00 %
C00632/3
L_NSet_1: max. skip frequency 3 0.00 %
C00633/1
L_NSet_1: Blocking speed 1 min 0.00 %
C00633/2
L_NSet_1: Blocking speed 2 min 0.00 %
C00633/3
L_NSet_1: Blocking speed 3 min 0.00 %
C00635
L_NSet_1: nMaxLimit 199.99 %
C00636
L_NSet_1: nMinLimit -199.99 %
C00670
L_OffsetGainP_1: Gain 1.0000
C00671
L_OffsetGainP_2: gain 1.0000
C00672
L_OffsetGainP_3: Gain 1.0000
efesotomasyon.com - Lenze