Firmware 05.00 - DMS 4.2 EN - 02/2010 L 605
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00097
C00097
C00098
C00099
C00100
C00101
Parameter | Name:
C00097 | Rated motor torque
Data type: UNSIGNED_32
Index: 24478
d
= 5F9E
h
Display of the rated motor torque
The value displayed here is calculated from different parameters, e.g. the maximum current set in C00022
.
Display range (min. value | unit | max. value)
0.00 Nm 65535.00
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00098 | Rated device current
Data type: UNSIGNED_16
Index: 24477
d
= 5F9D
h
Display of the rated inverter current which is defined by the integrated power section.
Display range (min. value | unit | max. value)
0.0 A 6000.0
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 10
Parameter | Name:
C00099 | Firmware version
Data type: VISIBLE_STRING
Index: 24476
d
= 5F9C
h
Display of the firmware version of the device as string
; Read access Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00100 | Firmware version
Data type: UNSIGNED_8
Index: 24475
d
= 5F9B
h
Display of the firmware version of the device, divided into subsections.
Display range (min. value | unit | max. value)
0 99
Subcodes Info
C00100/1 Firmware version - main version
C00100/2 Firmware version - subversion
C00100/3 Firmware version - release
C00100/4 Firmware version - build
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00101 | Add. acceleration time x
Data type: UNSIGNED_32
Index: 24474
d
= 5F9A
h
FB L_NSet_1: Additional acceleration times for the main setpoint
The additional acceleration times set here can be selected via the binary inputs bTI1 ... bTI8 of the L_NSet_1
FB.
Setting range (min. value | unit | max. value)
0.000 s 999.999
Subcodes Lenze setting Info
C00101/1 0.000 s Additional acceleration time 1 ... 15
C00101/...
C00101/15
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000