8400 HighLine | Parameter setting & configuration
Diagnostics & error management
Monitoring
464 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
9.6 Monitoring
The controller is provided with various monitoring functions which protect the drive
against impermissible operating conditions.
If a monitoring function responds,
– an entry will be made into the Logbook
of the controller,
– the response (TroubleQSP, Warning, Fault, etc.) set for this monitoring function will
be triggered,
– the status of the internal device control changes according to the selected response,
controller inhibit is set, and the "DRIVE ERROR" LED on the front of the controller goes
on:
Related topics:
LED status displays of the device state
( 454)
Device states
( 76)
Device overload monitoring (Ixt)
( 198)
Motor load monitoring (I2xt)
( 199)
Motor temperature monitoring (PTC)
( 201)
Brake resistor monitoring (I2xt)
( 202)
Motor phase failure monitoring
( 204)
Mains phase failure monitoring
( 205)
Maximum current monitoring
( 205)
Maximum torque monitoring
( 206)
Encoder open-circuit monitoring
( 207)
Response Entry in the
logbook
Display in
C00168
Pulse inhibit Controller
inhibit
Acknowledge
ment
required
LED
"DRIVE ERROR"
None Off
Fault
;;;;;
Trouble
;;;;
(after 0.5 s)
TroubleQSP
;; ;
Warning
Locked ;; ;
Warning
;;
Information ; Off
System error ;;;;Mains
switching
is required!
efesotomasyon.com - Lenze